Min/Max Dwell Time
C .1A <2.5R .001T .005S
The dwell defines how long a test will be performed in seconds. Dwell times are derived from Stimulus Value and Test Limit specifications.
Minimum Dwell Specified by letter “T”. The amount of time the system applies stimulus before measuring for Test Limit necessary for capacitive loads
Maximum Dwell Specified by letter “S”. The total amount of time the system applies stimulus.
The example continuity test specifies a minimum dwell time of .001 seconds, and a maximum dwell time of .005 seconds.
Source: NETS User Manual, Revision D, document 132-06035-0006, section 4.3.1.6.